AGILENT 34401A IVI-C DRIVER DOWNLOAD

Installing Software Refer to the instrument driver Readme file for detailed software requirements. Dottable properties have a blue glyph next to the property name. Automation Open and Initialize method. Click on the block diagram to place the Initialize method on the diagram. A dialog box appears, shown in Figure 1. Dotted properties are a shorthand alternative to cascading multiple Property Nodes that return interface references needed for wiring properties and methods specific to a given interface. Links to complete examples demonstrating how to execute the Measurement method and read the measured value are provided at the end of this document.

Uploader: Daitilar
Date Added: 16 April 2013
File Size: 27.42 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 63541
Price: Free* [*Free Regsitration Required]

Click on the block diagram to place the Initialize method on the diagram. This list can be long, so you might need to wgilent for keywords that match the driver, such as the vendor name or “IVI”.

Select a Web Site

Selecting help for Initialize method. An instrument driver is a set of software routines that control a programmable instrument.

Dotted properties are a shorthand alternative to cascading multiple Property Nodes that return interface 34401w needed for wiring properties and methods specific to a given interface. The block diagram should now appear similar to Figure 2.

Refer to the instrument driver help to determine the array data type. This is typically the first interface in the list.

Using an IVI-COM Instrument Driver in LabVIEW – National Instruments

This site uses cookies to offer you zgilent better browsing experience. A dialog box appears, shown in Figure 1. Selecting a dotted property. Converting variant data to an array See Also: The class interface changes and a new set of properties and methods are now selectable, shown in Figure 6.

Agilent Technologies / Keysight Technologies 34401A

Select the same type library you selected for the Automation Open refnum. Rate this document Select a Rating 1 – Poor 2 3 4 5 – Excellent. An example of how to access the help for the Initialize method is shown in Figure 9. Using the Class Browser. Using dotted properties and methods.

Instrument Control Toolbox Driver Search – MATLAB & Simulink

Instrument drivers simplify instrument control and reduce test program development time by eliminating the need to learn the programming protocol for each instrument. You should close references to all ActiveX sessions and interfaces when you are finished using them. In Figure 7notice that the sessions to the DCVoltage 3440a1 and to the driver session are closed after they are used.

Dottable properties have a blue glyph next to the property name. Links to complete examples demonstrating how to execute the Measurement method and read the measured value are provided at the end of agilentt document. Agilent IO Libraries Suite version Installing Software Refer to the instrument driver Readme file for detailed software requirements.

Automation Open and type library refnum. Automation Open and Initialize method. Learn more about our avilent policy. Each routine corresponds to a programmatic operation such as configuring, reading from, writing to, and triggering the instrument. You should consider all driver choices available, and choose the driver that best fits your needs.

Place a checkmark in the Show Creatable Objects Only check-box to display only objects that you can create.

The Type Library list contains the type libraries for all the jvi-c ActiveX servers on the system in alphabetical order. Figure 10 shows the Context Help window for the AutoRange property. Viewing context help for AutoRange property.